Flood Hazard and Structural Floodproofing
INEAS SD-100:26, clause 11. Preliminary draft. Values in this clause are under development and shall be confirmed against the final conservation authority guidance before use.
11 Flood hazard and structural floodproofing
11.1 General
11.1.1 This Clause applies where a building or ancillary structure is in or near a regulated flood hazard, or where its foundation, walls or slab are designed to resist flood loads. Floodproofing shall be designed by a P.Eng. (structural), and the method shall be shown on the grading, servicing and architectural sections.
11.1.2 The design flood shall be the Regulatory Flood Level (RFL) from the conservation authority geoportal, or as confirmed in writing by the authority. Where the authority uses the 1:100-year flood, the design shall use the 1:100-year flood elevation.
11.1.3 Floodproofing shall be stated as dry or wet on the plans. Avoiding flood-prone areas is the first measure, and the report shall say why a flood-free location was not used.
11.1.4 Regulated limits for the conservation authority area (RVCA or CRCA, as applicable): inland lake, the 100-year flood level plus wave uprush allowance plus 15 m; watercourse, top of channel bank plus 15 m; floodplain, mapped flood hazard plus 15 m; slope hazard, mapped erosion hazard plus 15 m (or a site-specific study); meander belt, 20 times bankfull width plus 15 m; dynamic beach, mapped hazard or 30 m from waterfront lands plus 15 m; wetland, mapped boundary plus 30 m. Wave uprush allowance: taken from the authority's Lake Ontario and St. Lawrence River 100-year flood level and wave uprush table for the nearest reference station, unless a site-specific study under 11.1.5 is accepted by the authority. The uprush value is added to the 100-year flood level; it does not replace it.
11.1.5 A site-specific wave uprush study shall be prepared where the shore has a slope, armour or geometry that the authority table does not cover, or where the authority requires it. The study shall (a) state the 100-year flood level, the still water level and the wave climate (significant wave height, peak period and depth at the toe) with their data source; (b) identify the shore slope, roughness and armour units; (c) calculate uprush with at least two methods that apply to the slope and wave conditions; and (d) state the applicability limits of each method used.
11.1.6 Regular-wave methods shall include Ahrens and McCartney (1975) and Stoa (1979) for rough slopes, with Losada and Gimenez-Curto (1981) as a check. Irregular-wave methods shall include Ahrens and Heimbaugh (1988) for riprap-protected slopes from 1:2 to 1:4, and Van der Meer and Stam (1992) for rock revetments and breakwaters. Rough-slope reduction factors shall be justified against the armour size.
11.1.7 The design uprush elevation shall be the 100-year flood level plus the greatest uprush from the selected methods, unless the authority accepts a lower value in writing with reasons. Results shall be tabulated by method, showing uprush, horizontal run, flood elevation and flood hazard elevation, and the governing value shall be identified.
11.1.8 Input data shall be checked before use. Where a wave period from a data source does not agree with the period implied by the wave height, the discrepancy shall be resolved and reported. Each method's applicability check shall be shown, including the depth ratio ds/H0' of 3 or more for Stoa, the slope range for each method, and the surf parameter range for Van der Meer and Stam.
11.2 Elevations
11.2.1 Underside of living space floor assembly (floor joists): RFL + 0.3 m.
11.2.2 Electrical and mechanical services (hot water tanks, furnaces, power boxes, outlets and ductwork): RFL + 0.3 m.
11.2.3 Openings in exterior walls (windows, doors, vents), dry floodproofing: RFL + 0.3 m.
11.2.4 Top of basement floor, dry floodproofing: RFL - 1.5 m.
11.2.5 Crawlspace height (basement floor surface to underside of joists), wet floodproofing: 1.8 m maximum.
11.2.6 Flood vents, wet floodproofing: the bottom of each vent no more than 0.15 m above grade, and the top of each vent below the RFL.
11.2.7 Top of drilled well air vents: 0.4 m above grade or 0.3 m above the RFL, whichever is greater.
11.2.8 Minimum roadway elevation for safe access: RFL - 0.3 m.
11.3 Floodproofing methods
11.3.1 Dry floodproofing: enclosed foundation with waterproofing; elevation on fill (side slopes not steeper than 3H:1V unless designed by an engineer, with erosion protection); elevation on columns or posts; or berms and walls.
11.3.2 Wet floodproofing: enclosed foundation with flood vents, or an open foundation or crawlspace.
11.3.3 Utilities: backflow prevention valves on sewage and drainage pipes; watertight sump covers, anchored against buoyancy; pumps with backup power; sealed sump discharge lines with check valves; manual shut-off valves on fuel lines; anchored oil and propane tanks; separate waterproof circuits for outlets, switches and lighting; small-diameter plastic conduit for wiring below the RFL.
11.3.4 Sump pumps shall not be relied on alone to resist buoyancy unless the wall and slab are designed for full hydrostatic force. Sump pumps can fail through mechanical fault, power loss, overload or frozen discharge.
11.4 Loads
11.4.1 Hydrostatic loads (lateral pressure on walls and buoyancy or uplift on slabs and foundations) shall be checked for every floodproofed foundation. Slabs shall span between foundations or beams, and foundations shall be checked against the uplift force with the weight of the structure above.
11.4.2 Hydrodynamic loads (front pressure, drag and suction from moving water) shall be checked where overland flooding occurs. Shear stress and scour at piers and footings shall be considered.
11.4.3 Ice and debris: where overland flooding exceeds 0.3 m, ice forces shall be considered in the design. A debris weight of 4.5 kN is recommended by the National Research Council (Guide for Design of Flood-Resistant Buildings, 2021). Impact loads are not a compulsory design condition, and the engineer applies them to the most critical member only.
11.4.4 Wave loads and the hydrodynamic, debris and ice loads applicable to lakeside structures shall be evaluated and stated in the design brief.
11.4.5 Waterproofing of basement floors on ground shall meet OBC 9.13.3.5 (membrane between two concrete layers, each not less than 75 mm thick, continuous with the wall membrane). [To be confirmed]
11.4.6 Where the RFL lies within a depth below the bearing surface of the foundation equal to the foundation width, the allowable soil bearing pressure shall be reduced by the factor set in OBC 9.4.4.3 [To be confirmed].
11.5 Flood openings for wet floodproofing
11.5.1 Each enclosed area shall have at least two openings, on opposite exterior walls. Openable windows on opposite sides are required by the MNR Technical Guide for River and Stream Systems: Flooding Hazard Limit (2002), Appendix 6 (Floodproofing) [To be confirmed].
11.5.2 Opening sills shall be no more than 150 mm above grade, and openings shall be below the RFL. Insect screens or grilles shall not block the flow. Detachable vent covers that are installed by hand do not satisfy this Clause.
11.5.3 Net open area shall be 1 in2 per 1 ft2 of enclosed area (prescriptive), or be calculated hydraulically for a rate of rise and fall of 5 ft per hour with a discharge coefficient of no more than 0.4. Net area excludes grilles. Openings in interior walls do not count toward the exterior area.
11.6 Drainage and site design
11.6.1 Grading shall direct water away from foundation walls. Reverse-slope driveways are prohibited (CSA Z800-18).
11.6.2 Window wells shall have a cover, and a drain to the foundation drainage system (CSA Z800-18).
11.6.3 Backfill shall be capped with an impermeable surface (fine-grained low-permeability soil, membrane or insulation board). The initial grade shall be exaggerated for settlement, and the cap shall extend beyond the excavation line (CSA Z800-18).
11.6.4 Foundation drains, backfill caps and window well drains are not reliable in a 1:100-year event. Dry or wet floodproofing shall still be provided. These measures reduce minor-event basement flooding for wet-floodproofed buildings.
11.6.5 Site changes shall not increase flood risk on adjacent or downstream properties.
11.7 Submission
11.7.1 The submission shall include site plan and grading sections with existing and proposed geodetic elevations confirmed by an OLS or P.Eng., foundation sections, building elevations and servicing plans.
11.7.2 The submission shall include a soils report, hydrostatic load calculations, bearing capacity calculations, and cut and fill volumes where earthwork changes the grades.
11.7.3 A hydraulic model report shall be provided where required by the authority, with input and output data, summary tables and mapping. [To be confirmed]
11.7.4 The plan or design brief shall state the flood velocity and flood depth, the soil bearing capacity, the reduction in bearing capacity where the RFL is within the foundation width, existing drainage infrastructure and stormwater systems, and safe ingress and egress routes during a flood.
11.7.5 Reports shall be reviewed against the technical review checklist for floodproofing reports (draft, March 2026).